Find great deals for Hörmann Universaladapterplatine UAP 1. Shop with confidence on eBay!. For Hörmann door, Type: SupraMatic, Rotamatic / P / PL from year 09/ and LineaMatic built from 10/ – About for direction selection (up / stop / close). For inputs to Hormann: does it mean that I have to run 6 wires for this section from Loxone to Hormann? Or is it possible to reuse the wire for

Author: Akinris Gorg
Country: Lithuania
Language: English (Spanish)
Genre: Spiritual
Published (Last): 23 June 2008
Pages: 163
PDF File Size: 2.47 Mb
ePub File Size: 10.92 Mb
ISBN: 427-9-66248-221-3
Downloads: 90158
Price: Free* [*Free Regsitration Required]
Uploader: Akinodal

That occured at baud 8N1 so I think that must be the correct baudrate. I might misinterprete some of them at this point: To dig deaper into the protocoll I need more data. Home Questions Tags Users Unanswered.

Move the door into the desired position with the buttons andvia the taught-in radio code impulse or an external control element with impulse function. Reverse engeneering the protocoll I expected a rather simple protocoll where no comunication happens until the UAP1 gets triggered by a switch, but I was more than wrong.

Connect potential free contacts directly to the motor. RX When the board is powered while the logic analyzer is collecting data, we see these bytes comming in: In my case it starts at address 0x8D which is in decimal. Address Ranges The patent gives a list of adresses for certain device categories: Why it doesnt scan the adresses down to ? I am an electronics amateur and can’t figure out based on the schematic below if that is correct? The status fully closed, fully open, mid drive works perfectly fine, however I am having issues with the motion commands move up, move down, stopas they only work sometimes and in some directions – which is most likely due to me wiring it up incorrectly however the guide linked above is not very specific about the wiring etc.

Dominik Hadl 51 4. Looking at the other link for the Hormann website using translation – it looks like they indicate it can do a partial open: Speak directly to the motor and get the signals directly onto the homeautomation system. It seems that this must happen when the UAP1 is connected to the motor. Thanks for looking into this! These are the messages I was able to make sense of so far.

  CONDORES NO ENTIERRAN TODOS LOS DIAS RESUMEN PDF

Bus scan At startup the Master scans the bus for devices.

Hi Ken, as you say in the beginning of the reply the UAP enables me to “open the garage door” and “close the garage door” which yap1 what I want to achieve same as what the person who wrote hromann guide I linked to achievedsorry if I didn’t explain properly.

Quiescent current circuit open Bit 4: If the selected height is too low, a 2-digit number starting with 1 will appear with a flashing decimal point see section No common CRC8 generator gave me the same result as the messages have.

Learning button assignment Bit 7: Email Required, but never shown. After having discussed that issue with my Italian friend he was able to figure out the polynom 0x07 as well as the initial value 0xF3 for the CRC algorithm.

Ken 4, 1 4 Therefore I plan to hook up the bus to a network outlet I have in my garage that leads all the way down into my basement where my network rack sits. Light on Bit 1: Radio control getting teached Bit 2: Sign up using Facebook. According to the Guide you posted The UAP enables you to control the light of the supramatic open the garage door close the garage door stop the garage door check whether the door is totally closed or totally open, light status?

When the board is powered while the logic analyzer is collecting data, we see these bytes comming in:. Exactly what I want to have: Top side kap1 the circuit board: Whith that one I can tell when the UAP1 is sending and when it is receiving!

Hörmann Universaladapterplatine UAP 1

Press the PRG button until the decimal point next to the menu number is illuminated. That tells me that it appears your UAP will not allow for the individual movements that you are looking to achieve. At startup the Master scans the bus for devices.

  ARATUS PISONII PDF

Option relay on Bit 3: They make me able to export the analyzed data as CSV. The remotes require a 2 second press to avoid accidental presses, have you tried making your pulse longer?

Later I captured traces using my logic analyzer for each possible command, these are: I jap1 to find the signals there as well but it turned out that is not the case. So I basically want a remotely controlled button the app where I click open and it will start moving up until the end position, which should be possible, and it sometimes does move or open, but something must be off with the connection, impulse duration or voltage as it does not work consistently: I found this guidewhich made the setup easier and I’ve setup everything hor,ann.

Unfortunately no other communication is happening when I trigger a “close door” for example. To supply the board with 24VDC, which normally comes in via the RJ12 connector, I simply used the terminals taht normally connect the switches.

I’ve set two analyzers for async serial data on both, the RX and the TX line. The CRC checksum After being able to seperate the byte stream into messages, I still wasn’t able to calculate the checksum.

Burglar alarm As you can see the only status bit set, is from the second byte and means reversing yormann to the patent which makes no sense to me.

low voltage – Hormann garage door opener automation with Loxone – Home Improvement Stack Exchange

Hardware Top side of the circuit board: So I decided to reverse engeneer and document the bus! Furthermore I’ve only see this reply all the time. I used the CRC calculator at http: